Virtualizing unRAID on Proxmox 6.0.4

Virtualizing unRAID on Proxmox 6.0.4 Хостинг

I have a proxmox instance with several Windows VMs.

I’ve restarted the VM on previous occasions and see the behavior each time.

The only difference between this one and the rest is that the Machine type in the «Hardware» tab is «q35» instead of «i440fx»

I tried googling this issue but results were not helpful.

Здравствуйте, господа. Имеется материнка ASRock J5005-ITX, где установлен Proxmox 6 поверх Debian 10. Осваимваю виртуализацию и пытаюсь пробросить интегрированную карточку Intel UHD Graphics 605 внутрь гостевой ОС Windows 10.

В /etc/default/grub прописал:

GRUB_CMDLINE_LINUX_DEFAULT=»quiet i915.enable_gvt=1 kvm.ignore_msrs=1 intel_iommu=on i915.enable_guc=0 video=efifb:off,vesafb=off vfio-pci.ids=8086:3184″

В /etc/modules прописал:

blacklist snd_hda_intel
blacklist snd_hda_codec_hdmi
blacklist i915

options vfio-pci ids=8086:3184 disable_vga=1

И, наконец, выполнил:

update-grub
update-initramfs -u -k all

kvm_intel 245760 0
kvmgt 28672 0
vfio_mdev 16384 0
mdev 24576 2 kvmgt,vfio_mdev
kvm 651264 2 kvmgt,kvm_intel
vfio_pci 49152 0
vfio_virqfd 16384 1 vfio_pci
vfio_iommu_type1 28672 0
vfio 32768 4 kvmgt,vfio_mdev,vfio_iommu_type1,vfio_pci
irqbypass 16384 2 vfio_pci,kvm

Подскажите, пожалуйста, почему не создаётся директория mdev_supported_types по пути /sys/bus/pci/devices/0000:00:02.0/?

On 7/30/2019 at 12:51 PM, Benson said:

Step almost the same, but I think best should be prepare unraid USB stick first then unplug it before prepare Proxmox.

Below are some detail

1. Unplug well prepare Unraid USB, best ( not must ) confirm it can boot in UEFI mode.

2. Install Proxmox to harddisk, make IOMMU enable.

3. Replug Unraid USB

4. Create VM

Virtualizing unRAID on Proxmox 6.0.4

4a. Tweak ( Some step may not necessary )

— Click CD/DVD drive, remove it

— Click Hard Disk, detach and remove it

Virtualizing unRAID on Proxmox 6.0.4

— Add phyical disk controller and physical Unraid USB stick

Virtualizing unRAID on Proxmox 6.0.4

Virtualizing unRAID on Proxmox 6.0.4

Virtualizing unRAID on Proxmox 6.0.4

— Edit boot order, only retain CD-ROM  in boot device_1

Virtualizing unRAID on Proxmox 6.0.4

so the steps I have takes.  I have created a Test UNRAID USB pen drive. — all works with no issues with a 4TB Hard Drive for storage.

Читайте также:  Редирект раскрыт: все, что вам нужно знать о его значении и влиянии

I then installed Proxmox onto a 1TB HD.

so far so good.

First I check the I have IOMMU Groups

Virtualizing unRAID on Proxmox 6.0.4

Virtualizing unRAID on Proxmox 6.0.4

then I created the VM

I did’t choose of OS as I was thinking that as I am passthrough my Unraid Pen drive, I will not need to set this up

working my way through

and it build OK then I when through and remvoe the CDROM and Added the Unraid Pen Drive.

then I confirm my boot order

but when I start my VM, then I am getting this

TASK ERROR: KVM virtualisation configured, but not available. Either disable in VM configuration or enable in BIOS.

and here is my Hard Spec

Оцените статью
Хостинги